- RS 제품 번호:
- 914-8495
- 제조사 부품 번호:
- SPP-N118-1421-1-4-001
- 제조업체:
- Simex
- RS 제품 번호:
- 914-8495
- 제조사 부품 번호:
- SPP-N118-1421-1-4-001
- 제조업체:
- Simex
참조 문서
제정법과 컴플라이언스
- COO (Country of Origin):
- PL
제품 세부 사항
SPI-N118/SPP-N118 Flow Meter
The SPI-N118 and SPP-N118 flow meters are designed to work together with flow transducers equipped with analogue inputs (SPP-N118) or contact/electronic inputs (SPI-N118). The purpose of the flow meter is to measure the instantaneous flow value and record the total flow of media like liquids, gases or loose materials.
The meters are encased in a tight, IP67 rated housing making them suitable for use in harsh environments. The SPI-N118 and SPP-N118 have built-in batcher function allowing the flow meters to be used in many industries such as food, pharmaceutical or paint and varnish.
The meters are encased in a tight, IP67 rated housing making them suitable for use in harsh environments. The SPI-N118 and SPP-N118 have built-in batcher function allowing the flow meters to be used in many industries such as food, pharmaceutical or paint and varnish.
6-digit (13 mm) LED display
Flow meter, batcher, totaliser
1 Pulse counting input & 3 control inputs (SPI-N118)
1 Input 0/4-20 mA & 1 programmable function input (SPP-N118)
Analogue output: active or passive
RS485/Modbus RTU communication port
Configuration by IR remote controller (914-8502) or with free S-Config software via RS485 communication port
Display of instantaneous and the total flow values
Batching and counting of doses
Wall mounted, IP67 housing
Flow meter, batcher, totaliser
1 Pulse counting input & 3 control inputs (SPI-N118)
1 Input 0/4-20 mA & 1 programmable function input (SPP-N118)
Analogue output: active or passive
RS485/Modbus RTU communication port
Configuration by IR remote controller (914-8502) or with free S-Config software via RS485 communication port
Display of instantaneous and the total flow values
Batching and counting of doses
Wall mounted, IP67 housing
Simex Multi function Meters
사양
속성 | 값 |
---|---|
Media Monitored | Fluid, Gas |
Device Type | Flow Counter |
Supply Voltage | 85 → 260 V ac |
Connection Type | Screw |
Maximum Pressure | 25kPa |
Material | ABS, Fibreglass |
Minimum Operating Temperature | 0°C |
Maximum Operating Temperature | +50°C |
Series | SPP |
Current Rating | 4 → 20 mA |